PIGNAT External Membrane Filtration – FME2000

Description

Water clarification by membrane filtration outer loop
 
Replacing the clarification basin biological treatment
  • Possible coupling station existing biological treatment
Management and optimization of operating cycles
  • Filtration cycle
  • Rest cycle
  • Retro‐wash cycle (backwashing of the membrane)
  • Automated sequence or manual operation

General Specifications

  • Peristaltic pump.
  • Compressed air circuit.
  • PMMA transparent column. Membrane hollow fiber technology.
  • Filtration loop, dosing pump.
  • Retro-wash.
  • Permeate tank, 3 L.
  • Storage tank 30 L.

Instrumentation

  • Flowmeter.
  • Manometer.
  • 5 management cycle electro valves.
  • Pressure transmitter.

Dim : 100 x 60 x 205 cm – 120 kg
SS tubular framework 40 x 40mm

For a complete product data sheet and a list of reference sites please call 1-877-967-2726.